INTRINSICALLY SAFE BARRIER RELAYS
Tuesday, October 4, 2022
Intrinsically Safe Barrier Relays
Intrinsically Safe Barrier Relays protect hazardous location circuits and control loads without additional relays or contactors. IS circuits operate at low energy levels that cannot ignite potentially explosives atmospheres. In the event of a fault condition, these Intrinsically Safe Barrier Relays prevent excess voltage and current from reaching the hazardous area.
When electrical equipment is used in, around, or near an atmosphere that has flammable gases or vapors, flammable liquids, combustible dusts, ignitable fibers or flyings, there is always a possibility or risk that a fire or explosion might occur. Those areas where the possibility or risk of fire or explosion might occur, due to an explosive atmosphere and/or mixture, are often called hazardous (or classified) locations. Currently, there are two systems used to classify these hazardous locations: the Class/Division system, used predominately in the United States, and the Zone system, generally used in the rest of the world.
WHAT’S NEEDED FOR AN EXPLOSION?
The most common types of reaction are between flammable gases, vapors or dust with oxygen in the surrounding air. As a rule, three basic requirements must be met for an explosion to take place in atmospheric air:
Flammable substance
Oxygen Source of Ignition (a spark or high heat)Note: both the flammable substance and the oxygen must be present in the correct mixture for the explosion to happen.
HOW IS THE EXPLOSION CONTROLLED?
The objective of selecting electrical equipment and the means of installation is to reduce the hazard of the electrical equipment to an acceptable level. The most certain method of preventing an explosion is to locate electrical equipment outside of hazardous (classified) areas whenever possible. In situations where this is not practical, installation techniques and enclosures are available which meet the requirements for locating electrical equipment in such areas. These methods of reducing hazards are based on the elimination of one or more of the elements of the ignition triangle discussed earlier.
Three principles ensure that electrical equipment does not become a source of ignition:
Contain the explosion: measures must be taken to ensure the explosion cannot spread to the surrounding atmosphere (explosion-proof enclosures or conduit & cable seals)Isolate the hazard: the surrounding atmosphere is prevented from entering the enclosure by maintaining a positive pressure of inert gas or clean air within the unit (pressurization and purging, oil immersion & hermetic sealing
Limit the energy: potentially explosive mixtures can penetrate the enclosure but must not be ignited. Sparks and raised temperatures must only occur within certain limits (intrinsic safety)All Macromatic IS Series Intrinsically Safe Barrier Relays follow the third principal: limit the energy utilizing an intrinsically safe circuit.
HAZARDOUS LOCATION CLASSIFICATIONS
Standard classification systems provide a concise description of the hazardous material that may be present along with the probability of it being present so that the appropriate equipment may be used and safe installation practices followed. In North America, the classification system most widely used is defined by the NFPA Publication 70, NEC and CEC. They define the type of hazardous substances that is or may be present in the air in sufficient quantities to produce an explosion. The NFPA establishes area classifications based on Classes, Divisions and Groups which are factors combined to define the hazardous conditions of a specific area. The table below summarizes the various hazardous (classified) locations: These are the Hazardous Location Classifications for the Macromatic ISD & ISE Series of Intrinsically Safe Barrier Relays:
Class I, Div 1 (Zones 0 and 1 in Canada), Group A, B, C, D
Class II, Div 1 (Zones 20 and 21 in Canada), Group E, F, G
Class III, Div 1The Macromatic ISD & ISE Series of Intrinsically Safe Relays have been tested and approved for listing under Underwriters Laboratory (UL) 913 Intrinsically Safe Apparatus and Associated Apparatus 8th Edition. The Macromatic ISP Series of Intrinsically Safe Relays have been tested and approved for listing under Underwriters Laboratory (UL) 913 Intrinsically Safe Apparatus and Associated Apparatus 6th Edition. The input or inputs to these devices have been approved for use in all Classes, Groups and Divisions.

|
|
Recent Posts
How to use Gateway Convertors Wednesday, March 10, 2021
Voltage Monitor Relays Wednesday, December 9, 2020
Why do you need a transformer ? Wednesday, June 10, 2020
Relays vs. Solenoids vs. Contactors: A Comparison Thursday, June 4, 2020
ABB Opens new distribution center in Phoenix! Thursday, May 28, 2020
Search Posts |
|
Blog Categories
General
12/09/2020 - Voltage Monitor Relays
02/13/2019 - 5 Benefits of Industrial Ether
02/06/2019 - Remarkable Benefits of Liquid
01/30/2019 - Electrical Protection of Induc
01/16/2019 - 5 Causes of Motor Failure and
01/02/2019 - Everything You Need to Know Ab
12/28/2018 - Different Types of Soft Starte
12/12/2018 - Different Types of Programmabl
12/05/2018 - Variable Frequency Drive
11/30/2018 - Applications of Programmable L
11/14/2018 - The Importance of Relays
11/07/2018 - Everything You Need to Know Ab
07/27/2018 - What Are Unearthed Outlets & W
07/11/2018 - The Difference between a Light
07/02/2018 - How Can I Stop My Smoke Detect
06/29/2018 - Understanding Operator Interfa
06/13/2018 - The Importance of Brand Authen
06/04/2018 - Stepper Motors for Machine Aut
04/16/2018 - The Use of Soft Starters and I
04/02/2018 - The Types & Advantages of Usin
03/27/2018 - The New Designs of Contact Blo
03/27/2018 - Important Things You Need to K
03/14/2018 - Limit Switches Improve Safety
03/05/2018 - Soft Starters- Advantages, Typ
02/27/2018 - 8 Reasons to Use a Fuse
02/16/2018 - 4 Benefits of Programmable Log
02/06/2018 - 3 Reasons Why Circuit Breakers
01/29/2018 - 2 Gas Based Generators You Did
01/18/2018 - Common Types of Generators You
01/05/2018 - 3 Machine Safety Measures That
Enclosures
02/23/2019 - Different Types of Electrical
10/31/2018 - The importance of installing e
08/06/2018 - Metal or Plastic? How About Ne
Circuit Protection
09/12/2018 - Why Are Fuses Important?
08/31/2018 - Miniature Circuit Breakers: Ty
08/15/2018 - Miniature Circuit Breakers: Ty
05/30/2018 - How to Replace a Fuse
05/21/2018 - Circuit Breaker vs. Fuse: Whic
05/07/2018 - All You Need to Know About Cir
04/02/2018 - 5 Reasons Why Circuit Breakers
01/01/2018 - ABB Terminal Blocks Are Child’
01/25/2016 - Why Do You Want Miniature Circ
01/12/2016 - Lovato Now At Midwest Equipmen
Machine Safety
Midwest Enclosures
ABB New Facility
Relays vs. Solenoids vs. Contactors: A Comparison
Transformers
Gateway Convertors
New Mersen Product !
Supply Chain Shortages
Why is Motor Control Important ?
What Do Time Switches Do?
Understanding Time Delay Relay Functions
Using Liquid Level Control Relays
Intrinsically Safe Relays
|
Subscribe To Our Blog |
|