  RTA 460MMBMS-N34-D Converter Gateway, Connects up to 32 Modbus RTU Slaves With A BACnet MS/TP Master
 
$825.00
   
   
  

Product Photos
right left

Product Description
RTA 460MMBMS-N34-D Converter Gateway, Connects up to 32 Modbus RTU Slaves With A BACnet MS/TP Master
Connect Modbus RTU Slaves to a BACnet MS/TP System

The 460MMBMS moves data between up to 32 Modbus RTU Slaves and a BACnet MS/TP Building Automation System (BAS). It’s a perfect tool to tie Modbus power meters, boilers, chiller and other devices into your BACnet MS/TP Building Automation System.

Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

Connect Modbus RTU Slaves to a BACnet MS/TP System
The 460MMBMS moves data between up to 32 Modbus RTU Slaves and a BACnet MS/TP Building Automation System (BAS). It’s a perfect tool to tie Modbus power meters, boilers, chiller and other devices into your BACnet MS/TP Building Automation System.

Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

How Do I Use the 460MMBMS in My Application?
For most applications the mapping is very straight forward. Modbus register data is mapped to BACnet analog objects and Modbus coil data is mapped to binary objects on BACnet. The only additional piece required for BACnet is adding meta data which is nothing more than an ASCII description of each object. No other deep understanding of either protocol is required to configure the gateway.

It really is that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Move Your Data Bi-directionally
You can both send and receive data to and from your Modbus RTU Slave devices. Registers and Coils in the Modbus RTU Slaves are mapped directly to BACnet MS/TP properties of Analog Input, Analog Output, Binary Input, and Binary Output. Up to 150 Analog Inputs, 150 Analog Outputs, 1600 Binary Inputs, and 1600 Binary Outputs can be mapped to Registers and Coils in up to 31 Modbus RTU Slave devices.

Why Use Real Time Automation as a Gateway Supplier?
The 460MMBMS provides an option to access Modbus RTU Slave devices on your BACnet MS/TP Master. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from Midwest and RTA.

Weight 1.00 lbs

You Might Also Like

Wiegmann ALN

Jokab 2TLA02

EXM 5412ESS2

ABB, 60 Amp

Wiegmann RHC

Wiegmann N1C

Wiegmann N1C

Wiegmann SC0

Wiegmann N41

TrueMeter, A

ABB eOT16U3P

Idec HG9Z-SC
 

NEWSLETTER SIGN UP

Subscribe for our newsletter program.


Home
Credit/Tax Apps
Sell On Midwest
Government Buyers

 

Order Policy
Shipping Terms
Privacy
My Account


Midwest Equipment
6555 Corporate Drive, Cincinnati, OH 45242
1 (888) 261-3076
Message Us


Follow Us on FacebookFollow us on TwitterFollow us on LinkedInBlog

COPYRIGHT © 2020. MIDWEST EQUIPMENT. ALL RIGHTS RESERVED.